Data Hall — overhead structured cabling
Wire-Mesh Cable Trays route structured cabling above the server rack rows in an open, ventilated construction, matching the Data Centre Application Map's own data hall reference.

Please wait while the page is prepared.
DATA CENTRE CABLE CONTAINMENT
Wire-mesh cable trays, cable ladders, cable tray systems and support/hanging systems route power, control and data cabling through data hall, riser, electrical room and plant spaces — coordinated with the power and cooling infrastructure around them. InfraVolt provides technical-commercial project support for UK data centre projects.

Gersan manufactures the cable management systems shown on this page. InfraVolt supports UK and Ukraine projects with system selection, technical-commercial coordination and enquiries.
Wire-Mesh Cable Trays provide flexible, open overhead structured-cabling routes above server rack rows. Cable Ladder Systems carry high-capacity routes, including electrical riser routing between floors. Cable Tray Systems route power, control and data cabling through electrical rooms, plant spaces and general service routes. Support & Hanging Systems — profiles, brackets, consoles and threaded rods — carry all of the above on walls, ceilings, floors or structural steelwork. No single system replaces the others; the right choice depends on the route and load.
Wire-Mesh Cable Trays route structured cabling above the server rack rows in an open, ventilated construction, matching the Data Centre Application Map's own data hall reference.
Cable Ladder Systems route power and data cabling alongside the busbar riser between floors, carrying high-capacity runs through the vertical electrical riser.
Cable Management routes carry power and control cabling overhead between switchgear, UPS equipment and adjoining rooms — the specific tray, ladder or wire-mesh construction is selected per project.
Overhead cable-management routes connect generators, switchgear, chillers and pumps to distribution panels. Route, cable load, support arrangement and material/finish are selected per project — no environmental rating is assumed.
Support & Hanging Systems — profiles, brackets, consoles, threaded rods and suspension components — carry tray, ladder and wire-mesh routes from walls, ceilings, floors or structural steelwork.
Four Gersan cable management systems are relevant to data centre cable routing, each suited to a different role. None is a universal replacement for the others.
| System | Data-centre role | Construction / selection note | Product page |
|---|---|---|---|
| Wire-Mesh Cable Trays | Flexible overhead structured cabling — strongest evidence for data hall routes above rack rows | Open, ventilated, lightweight construction; multiple tray heights with matching jointing and support accessories | Wire-Mesh Cable Trays |
| Cable Ladder Systems | High-capacity routes, including electrical riser routing between floors | C-Profile Rung, Heavy Duty, GCMC and GMIE Type scope, with directional accessories | Cable Ladder Systems |
| Cable Tray Systems | Power, control and data cable routing through electrical rooms, plant spaces and general service routes | Perforated, strengthened, heavy-duty and trunking variants, selected per project | Cable Tray Systems |
| Support & Hanging Systems | Structural support layer that carries tray, ladder and wire-mesh containment | Profiles, brackets, consoles and threaded rods for wall, ceiling, floor and multi-level mounting | Support & Hanging Systems |
The current Gersan Cable Management category documentation lists BS EN 61537 and IEC 61537 as applicable standards. Product-family applicability, load data, material/finish and installation details should be confirmed against the relevant technical documentation for the project.
Wire-Mesh Cable Trays for data hall overhead routing, Cable Ladder Systems for high-capacity and riser routes, Cable Tray Systems for electrical room and plant routing, and Support & Hanging Systems to carry all of them.
Wire-mesh cable tray is used for flexible, open, ventilated overhead structured-cabling routes — most commonly above server rack rows in the data hall.
Cable ladders are relevant for high-capacity routes, including the electrical riser, where they route power and data cabling between floors.
Support & Hanging Systems — profiles, brackets, consoles and threaded rods — carry cable tray, cable ladder and wire-mesh routes from walls, ceilings, floors or structural steelwork.
The current Gersan Cable Management category documentation lists BS EN 61537 and IEC 61537 as applicable standards. Confirm applicability against the relevant technical documentation for your project.
No. Gersan is the manufacturer. InfraVolt is the distributor and market representative, and the technical-commercial project contact for UK and Ukraine.
Use the Request Quote or Request Technical Pack links on this page to send your requirement to InfraVolt's technical team.
The Data Centre Application Map is an interactive visual showing where Cable Management and InfraVolt's other product families may be used across a data centre — from the main electrical room and data hall to the electrical riser and cooling plant.
PROJECT SUPPORT
Share your current route, cable load and project stage with our technical team.